Installing the VoIP Outdoor Intercom with Keypad
Intercom Setup
Operations Guide 930809M CyberData Corporation
38
Note The maximum number of total characters in the dial-out field is 25.
2.4.6.2 Triggering a Dial Out Call or Security Code
You can instantly trigger a dial out call or security code by pressing the # key after dialing a number.
Ta b l e 2-14 shows the various actions that result from different keypad input.
Allow Telephone Dialout Option Enabled (in security mode with default security settings)
Input Resulting Action
The device will instantly call extension 123 through the default SIP
server.
Allow Telephone Dialout Option Disabled (in security mode with default security settings)
Input Resulting Action
Table 2-14. Triggering a Dial Out Call or Security Code
Dialing 123
(and waiting for several seconds)
The device will call extension 123 through the default SIP server.
Dialing #123
(and waiting for several seconds)
The device will do nothing. The entry is an unrecognized security
entry.
Dialing #1234560
(and waiting for several seconds)
The device will activate the relay for Security Code 0 for 6 seconds.
Dialing #124560# The device will instantly activate the relay for 6 seconds.
Dialing 123#
Dialing 123
4560
(and waiting for several seconds)
The device will activate the relay for Security Code 0 for 6 seconds.
Comentários a estes Manuais