Mounting the Intercom
Wall Mounting
Operations Guide 930853D CyberData Corporation
69
A.3 Wall Mounting
Figure A-4 illustrates a wall mounting option for the VoIP Flush-Mount Indoor Intercom.
Figure A-4. Wall Mounting
To mount the Intercom:
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in Section A.4, "Ground Cable Installation") and the network cable
from the wall cutout through the knockout hole of the gang box.
4. Create a service loop for both the ground wire and network cable.
5. Plug the network cable into the J1 connector.
6. Make sure that the arrow labels are pointing up. This will ensure that the intrusion sensor
functions properly.
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
Fold Down all Flagnuts (4 Places)
before Inserting into Wall Cutout
Cutout
Network Cable
(Not Provided)
Screws
Faceplate
2 Gang Box
Torx Drive)
Assembly
Ground Wire &
Point Upward.
Arrow Labels must
This will Ensure that
the Intrusion Sensor
Functions Properly.
Wall
Inside Gang Box
Create Service Loop
Torx Key
(Phillip Drive)
(Security
Mounting
Screws
Mounting
Flagnuts
(4 Places)
K.O.
to J1
6.03 inches
[153mm]
5.28 inches
[134mm]
Network Cable
J1
Intrusion
Sensor
1
8
7
3
9
9
4
6
2
5
Custom
Enclosure
Create Service Loop
Inside Custom Enclosure
Note: To mount the intercom, use methods
compliant with local electrical codes.